AC power supplies have a C14 connector. For factory-installed upgrades, either Standard to Advanced Upgrade (feature AVUT) or Standard to Enterprise Upgrade (feature AUPW) can be selected, but not both. Pointing Device USB - Japanese 194 RoHS v2, ThinkSystem Keyboard w/ Int. ** The CMA Upgrade Kit for Screw-in Slide Rail is supported with the Screw-in Slide Rail (4M17A07274) only. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/. Matrox G200e with 16 MB memory integrated into the XClarity Controller. Offers flexible and scalable internal storage in a 2U rack form factor with up to 24x 2.5-inch and 2x 3.5-inch drives for performance-optimized configurations or up to 14x 3.5-inch drives for capacity-optimized configurations, providing a wide selection of SAS/SATA HDD/SSD and PCIe NVMe SSD types and capacities. Pointing Device USB - Turkish 179 RoHS v2, ThinkSystem Keyboard w/ Int. Up to six PCIe expansion slots (depending on the riser cards selected). http://support.lenovo.com.cn/lenovo/wsi/es/es.html. Pointing Device USB - Japanese 194 RoHS v2, ThinkSystem Keyboard w/ Int. Lenovo XClarity Energy Manager provides a stand-alone, web-based agent-less power management console that provides real time data and enables you to observe, plan and manage power and cooling for Lenovo servers. The following figure shows the front of the SR550 server with up to 16x 2.5-inch drive bays. Maximum resolution is 1920x1200 at 60 Hz with 32 bits per pixel. * The maximum quantity shown is with one processor / two processors. Encrypts files to ensure data safety by using the TCM or Nationz TPM. The SR650 server supports up to four onboard network ports with optional LOM cards that use the Intel Ethernet Connection X722 1/10 GbE technology integrated into the Intel C624 Platform Controller Hub (PCH). Capacity Planner can dynamically calculate the power consumption, current, British Thermal Unit (BTU), and volt-ampere (VA) rating at the rack level, improving the planning efficiency for large scale deployments. Lenovo offers the ThinkSystem DB Series of Fibre Channel SAN switches and directors for high-performance storage expansion. deep if a CMA is used. Slots 1 - 3 are not present if the Rear HDD Kit is installed. Pointing Device USB - Greek 219 RoHS v2, ThinkSystem Keyboard w/ Int. The 128 GB Performance+ 2933 MHz 3DS RDIMMs (feature code B5N9) running at 2933 MHz with two DIMMs per channel are supported at the ambient temperature of up to 30 °C (86 °F). Pointing Device USB - Arabic 253 RoHS v2, ThinkSystem Keyboard w/ Int. Slot 1: PCIe 3.0 x16 or PCIe 3.0 x8; full-height, half-length (PCIe x16 slot is double-wide), Slot 2: PCIe 3.0 x8; full-height, half-length (not present if the slot 1 is PCIe x16), Slot 3: PCIe 3.0 x8 or ML2 x8; full-height, half-length, Slot 4: PCIe 3.0 x8; low profile (vertical slot on system planar), Slot 5: PCIe 3.0 x16; full-height, half-length, Slot 6: PCIe 3.0 x8; full-height, half-length. Figure 5. RackSwitch The kit provides support for up to three GPUs or full-length adapters in the PCIe x16 slots 1, 5, and 6, and it contains an air duct, two low-profile heatsinks, and two full-length card holders. For Mixed Memory Mode, the volatile (Memory) portion of the total capacity of DCPMMs is configured in increments of 32 GB multiplied by the number of DCPMMs in the server, and the remaining capacity is allocated to the persistent (App Direct) portion. RackSwitch Lenovo Enterprise Software Support is an additional support service that provides customers with software support on Microsoft, Red Hat, SUSE, and VMWare applications and systems. Pointing Device USB - Norwegian 155 RoHS v2, ThinkSystem Keyboard w/ Int. * NA = North America; AP = Asia Pacific. Keeps user data safe with Lenovo Business Vantage, a security software tool suite designed to work with the Trusted Cryptographic Module or Nationz TPM (available only in PRC). The ThinkSystem SR650 server offers the following security features: The server is NIST SP 800-147B compliant. Quarterly reviews check error logs, verify firmware & OS device driver levels, and software as needed. Flash storage adapters are supported only with processors of up to 165 W TDP. The following table lists supported combinations of the DCPMMs and memory DIMMs available for the SR650 server. For models with 16/20/24x 2.5" U.2 NVMe PCIe drive bays (either factory-installed or upgraded in the field), the following conditions must be met: Two processors with up to 165 W TDP installed. Memory DIMMs and persistent memory modules: App Direct Mode: Up to 7.5 TB with up to 12x 128 GB 3DS RDIMMs and up to 12x 512 GB DCPMMs (Up to 3.75 TB per processor). Lenovo XClarity Administrator is an optional software component for the SR550 server which can be downloaded and used at no charge to discover and monitor the SR550 and manage firmware upgrades for them. ^ Field upgrade only. By default, the SR550 server includes XClarity Controller Standard features, and it can be upgraded to Advanced or Enterprise functionality by using the Features on Demand (FoD) upgrades. Flash storage adapters are supported only in the environments with an ambient temperature of up to 35 °C (95 °F). Figure 4. AC power supplies support AC (Worldwide) and HVDC (PRC only) power sources. http://lenovopress.com/servers/options/ethernet#rt=product-guide. Support staff can answer troubleshooting and diagnostic questions, address product compatibility and interoperability issues, isolate causes of problems, report defects to software vendors, and more. The following table lists available PCIe riser card options. * HBAs do not support key management for SEDs; third-party host software is responsible for managing the keys. Note: This product guide describes SR550 server models with the second generation of the Intel Xeon Processor Scalable Family (Xeon SP Gen 2). Our highly experienced team of finance professionals operates in a work culture that emphasizes the importance of providing outstanding customer service. This mode is considered particularly suited for in-memory databases, in-memory analytics frameworks, and ultrafast storage applications. Pointing Device USB - Portugese 163 RoHS v2, ThinkSystem Keyboard w/ Int. Provides I/O scalability with a LOM slot and up to six PCI Express (PCIe) 3.0 I/O expansion slots in a 2U rack form factor. deep. ), depth: 764 mm (30.1 in.). The SR650 server is designed to handle a wide range of workloads, such as databases, virtualization and cloud computing, virtual desktop infrastructure (VDI), enterprise applications, collaboration/email, and business analytics and big data. Professional Services consultants perform infrastructure design and implementation planning to support customer's strategy. Supported in the uniprocessor configurations only. XClarity Controller offers three functional levels: Standard, Advanced, and Enterprise. Speeds up troubleshooting tasks to reduce service time with diagnostics built into the XClarity Provisioning Manager. The high-level architectures provided by the assessment service are turned into low level designs and wiring diagrams, which are reviewed and approved prior to implementation The implementation plan will demonstrate an outcome-based proposal to provide business capabilities through infrastructure with a risk-mitigated project plan. Front view of the SR550: 8x 3.5-inch drive bays. The Lenovo ThinkSystem SR550 dual-socket 2U rack server is ideal for small to large organizations that need industry-leading reliability, management, and security, as well as cost If software support is required for Lenovo XClarity Administrator, or Lenovo XClarity Administrator premium features (such as configuration management and operating system deployment) are required, or both, Lenovo XClarity Pro software subscription should be ordered. Slot 1: PCIe 3.0 x16 or PCIe 3.0 x8; full-height, half-length (PCIe x16 slot can be single- or double-wide), Slot 2: PCIe 3.0 x8; full-height, half-length (not present if Slot 1 is PCIe x16 double-wide or Slot 3 is ML2 x16), Slot 3: PCIe 3.0 x8, or PCIe 3.0 x16, or ML2 x8, or ML2 x16; full-height, half-length, Slot 4: PCIe 3.0 x8; low profile (vertical slot on system planar), Slot 5: PCIe 3.0 x16; full-height, half-length, Slot 6: PCIe 3.0 x16; full-height, half-length, Slot 7: PCIe 3.0 x8 (for an internal storage controller). https://lenovopress.com/servers/options/backup. For more information, see the list of Product Guides in the Backup units category: Optional service upgrades are available through Lenovo Services: 2-hour or 4-hour response time, 6-hour or 24-hour committed service repair (select areas), warranty extension up to 5 years, 1-year or 2-year post-warranty extensions, YourDrive Your Data, Enterprise Software Support, and Basic Hardware Installation Services. Lenovo ThinkSystem SR650 is an ideal 2-socket 2U rack server for small businesses up to large enterprises that need industry-leading reliability, management, and security, as well as maximizing performance and flexibility for future growth. These models support adding drive bays by using the 3.5" 8-drive backplane kit (4XH7A08770) or 3.5" 12-drive backplane kit (4XH7A08771). Persistent memory is not supported in configurations with GPU adapters, Persistent memory is not supported in configurations with flash storage adapters, 4x 2.5" SAS/SATA & 4x 2.5" AnyBay + 8x 2.5" SAS/SATA + 2x 3.5" SAS/SATA, 4x 2.5" SAS/SATA & 4x 2.5" AnyBay + 4x 2.5" SAS/SATA & 4x 2.5" AnyBay +, 8x 2.5" SAS/SATA + 8x 2.5" SAS/SATA + 8x 2.5" SAS/SATA + 2x 3.5" SAS/SATA, 4x 2.5" SAS/SATA & 4x 2.5" AnyBay + 8x 2.5" SAS/SATA + 8x 2.5" SAS/SATA +, 4x 2.5" SAS/SATA & 4x 2.5" AnyBay + 4x 2.5" SAS/SATA & 4x 2.5" AnyBay + 8x 2.5" SAS/SATA +, Up to 10 LFF SAS/SATA hot-swap drive bays: 8x 3.5" SAS/SATA (front) + 2x 3.5" SAS/SATA (rear), 8x 3.5" SAS/SATA & 4x 3.5" AnyBay (front) +. Adaptive Double Device Data Correction (ADDDC) works with x4-based memory DIMMs and requires two DIMM ranks per channel, Intel Xeon Gold or Platinum processors, and the Closed Page memory access mode. All DIMMs in the server must be identical in type and size. The GPU adapters require the PCIe x16 riser cards (except T4. Lenovo's goal for customers is to reduce capital outlays, mitigate IT risks, and accelerate time to productivity. Lenovo ARS is a cash-back solution for equipment based on its remaining market value, yielding maximum value from aging assets and lowering total cost of ownership for customers. The server supports the external USB optical drive listed in the following table. ), depth: 764 mm (30.1 in.). * The CMA Upgrade Kit for Tool-less Slide Rail is supported with the Tool-less Slide Rail (7M27A05702) only. The following figure shows the front of the SR650 server with 8x 3.5-inch drive bays. The following tables list supported internal storage configurations with the SAS/SATA and AnyBay backplanes. If warranty terms and conditions include onsite labor for repair or replacement of parts, Lenovo will dispatch a service technician to the customer site to perform the replacement. Boosts the performance of data-intensive applications and delivers consistent service levels at scale for virtualized and cloud environments by using the innovative persistent memory technology that provides a unique combination of affordable large memory capacity and non-volatility for up to 7.5 TB of total server memory capacity, including 3DS RDIMMs and DCPMMs (DC persistent memory modules). Figure 8. Internal storage configurations tables convention: The numbers in brackets (x or x+y or x+y+z) in the Storage controller column specify the quantity of drive bays connected to each of the controllers. The slots that are available for use depend on the number of riser cards that are installed and whether the second processor is installed, as shown in the following table. Lenovo’s YourDrive YourData service is a multi-drive retention offering that ensures that customer's data is always under their control, regardless of the number of drives that are installed in their Lenovo server. For server configurations with memory protection, the following rules apply: Single Device Data Correction (SDDC) works only in the independent channel mode and supports only x4-based memory DIMMs. The server performance might be impacted in case of a system fan failure. * The adapter comes without transceivers or cables; for ordering transceivers or cables, see the product guide for the adapter. TopSeller ThinkSystem DB Series SAN Switches and Directors: 3D Interactive Tour of the ThinkSystem SR650: Walkthrough Video for the ThinkSystem SR650: Lenovo Data Center Support Downloads - ThinkSystem SR650: Lenovo Hardware Installation & Removal Videos on the ThinkSystem SR650: Lenovo Data Center Solution Configurator (DCSC): Added the following new model for Brazil -, ThinkSystem NVIDIA A100 40GB PCIe Gen4 Passive GPU, 4X67A13135, New Riser 2 V2 Kit replacing the existing Riser 2 kit -, ThinkSystem SR650 x16/x8(or x16) PCIe FH Riser 2 Kit V2, 4TA7A70026, ThinkSystem Marvell QL41232 10/25GbE SFP28 2-Port PCIe Ethernet Adapter, 4XC7A08270, SiNEAD I350-C4 PCIe 1Gb 4-Port RJ45 Ethernet Adapter, 4XC7A62589 (only available in China). The maximum server memory that can be installed with the NVIDIA Tesla M10. The DCPMMs support the following modes of operation: Memory Mode seamlessly brings large memory capacity at affordable cost points to legacy applications. * The CMA Upgrade Kit for Tool-less Slide Rail is supported with the Tool-less Slide Rail (7M27A05702) only. Lenovo Data Center Solution Configurator (DCSC), System x and Cluster Solutions Configurator (x-config), Association of Southeast Asian Nations (ASEAN), http://lenovopress.com/servers/options/raid#rt=product-guide, http://lenovopress.com/servers/options/hba#rt=product-guide, http://lenovopress.com/servers/options/ethernet#rt=product-guide, http://datacentersupport.lenovo.com/us/en/solutions/lnvo-lcp, http://support.lenovo.com/us/en/documents/LNVO-center, http://www3.lenovo.com/us/en/data-center/software/systems-management/xclarity-integrators, http://datacentersupport.lenovo.com/us/en/solutions/lnvo-lxem, http://support.lenovo.com.cn/lenovo/wsi/es/es.html, https://lenovopress.com/osig#servers=sr550-7x03-7x04-sp-gen-2, http://pcsupport.lenovo.com/us/en/solutions/ht503310, http://support.lenovo.com/us/en/solutions/ht116628, https://lenovopress.com/storage/thinksystem/de-series#rt=product-guide, https://lenovopress.com/storage/thinksystem/dm-series#rt=product-guide, https://lenovopress.com/servers/options/backup, http://lenovopress.com/servers/options/switches#rt=product-guide, https://lenovopress.com/storage/switches/rack#rt=product-guide, http://lenovopress.com/servers/options/racks#rt=product-guide, http://lenovopress.com/servers/options/kvm#rt=product-guide, http://lenovopress.com/servers/options/pdu#rt=product-guide, http://lenovopress.com/servers/options/ups#rt=product-guide, http://www.lenovo.com/us/en/landingpage/lenovo-financial-services, https://www.lenovo.com/us/en/data-center/servers/racks/ThinkSystem-SR550/p/77XX7SRSR55, https://lenovopress.com/ds0030-lenovo-thinksystem-sr550, https://lenovopress.com/lp0671-3d-tour-thinksystem-sr550, https://lenovopress.com/lp0745-thinksystem-sr550-server-video-walkthrough, https://thinksystem.lenovofiles.com/help/topic/7X03/introduction.html?cp=4_3, http://datacentersupport.lenovo.com/products/servers/thinksystem/sr550/7x03/downloads, http://datacentersupport.lenovo.com/products/servers/thinksystem/sr550/7x04/downloads, https://www.youtube.com/playlist?list=PLYV5R7hVcs-C9jFjZnXQ6AmTXaIdX6_HJ, https://list.youku.com/albumlist/show/id_50429987, https://www.lenovo.com/us/en/legal/copytrade/. The SR550 server offers a balance of processing power, storage capacity, and cost for small and medium businesses up to the large enterprise. ** Factory-installed only; no field upgrade. Pointing Device USB - Italian 141 RoHS v2, ThinkSystem Keyboard w/ Int. The Bootable Media Creator (BOMC) tool is used to create bootable media for offline firmware update. Continuously monitors system parameters, triggers alerts, and performs recovery actions in case of failure to minimize downtime with Built-in XClarity Controller (XCC). Other company, product, or service names may be trademarks or service marks of others. The SR550 server supports up to two processors, up to 768 GB of 2933 MHz TruDDR4 memory, up to 16x 2.5-inch or up to 12x 3.5-inch drive bays with an extensive choice of SAS/SATA SSDs and SAS/SATA HDDs, and flexible and scalable I/O expansion options with a LOM slot and up to 6x PCIe slots. ** If a 0U PDU used, the rack must be at least 1000 mm (39.37 in.) Two 1 Gb Ethernet ports (no 10/100 Mb Ethernet support), Two 1/10 Gb Ethernet capable ports (no 10/100 Mb Ethernet support), NIC Teaming (load balancing and failover), VMDq and SR-IOV virtualization (10 Gb speeds only, 4 PFs, 128 VFs per device), IEEE 802.1q Virtual Local Area Networks (VLANs), NVGRE, VXLAN, IPinGRE, and MACinUDP network virtualization, Large Send Offload (LSO) and Generic Send Offload (GSO), Receive Side Scaling (RSS) for TCP and UDP traffic. Gold 6230T, 6246, or 6252N processors are supported in the following hardware configurations: 4x 2.5" SAS/SATA and 4x 2.5" AnyBay drive bays. Allows preventive actions in advance of possible failure, thereby increasing server uptime and application availability with Proactive Platform Alerts (including PFA and SMART alerts) for processors, voltage regulators, memory, internal storage (SAS/SATA HDDs and SSDs, M.2 storage), fans, power supplies, RAID controllers, and server ambient and sub-component temperatures. ‡ Models with 8, 16, or 24 SFF drive bays can be upgraded with 2 additional LFF rear drive bays (See Internal storage for details) that are not included in the maximum quantity shown. Lenovo Managed Services provides continuous 24x7 remote monitoring (plus 24x7 call center availability) and proactive management of a your data center using state of the art tools, systems, and practices by a team of highly skilled and experienced Lenovo services professionals. ), height: 87 mm (3.4 in. http://lenovopress.com/servers/options/kvm#rt=product-guide. Centralizes infrastructure resource management with Lenovo XClarity Integrators for VMware vCenter and Microsoft System Center, extending XClarity Administrator features to virtualization management software tools and enabling users to deploy and manage infrastructure end-to-end. ‡ Models with 8, 16, or 24 SFF drive bays can be upgraded with 2 additional LFF rear drive bays (See Internal storage for details) that are not included in the maximum quantity shown. By default, the SR650 server includes XClarity Controller Standard features, and it can be upgraded to Advanced or Enterprise functionality by using the Features on Demand (FoD) upgrades. Ambient temperature of up to 30 °C (86 °F). PCIe 4.0 NVMe drive support: When installed in this server, PCIe 4.0 NVMe drives will operate at PCIe 3.0 speeds. Models without any drive bays that are based on the 16x 2.5" chassis (feature code AV0R) support adding drive bays by using the 2.5" 8-drive backplane kit (7XH7A06254). In the unlikely event of a drive failure, you retain possession of your drive while Lenovo replaces the failed drive part. For more information about the server configurations with 16/20/24x 2.5-inch U.2 NVMe PCIe drive bays, refer to the NVMe-Rich Configurations of the ThinkSystem SR650 article: http://lenovopress.com/servers/options/hba#rt=product-guide. * The maximum quantity shown is with one processor / two processors. The second processor must be of the same model as the first processor. These models support adding drive bays by using the 3.5" 8-bay backplane kit (4XH7A08770), 3.5" 12-bay backplane kit (4XH7A08771), or 3.5" AnyBay 12-bay backplane kit (4XH7A08785). Our systems, processes and flexible policies support our goal of providing customers with a positive experience. Pointing Device USB - Czech 489 RoHS v2, ThinkSystem Keyboard w/ Int. Pointing Device USB - Korean 413 RoHS v2, ThinkSystem Keyboard w/ Int. Pointing Device USB - US Euro 103P RoHS v2, Console switches and cables - ThinkSystem Digital KVM, ThinkSystem Digital 2x1x16 KVM Switch (DVI video output port), ThinkSystem Single-USB Conversion Cable for Digital KVM, ThinkSystem Dual-USB Conversion Cable for Digital KVM, Console switches and cables - ThinkSystem Analog KVM, ThinkSystem Analog 1x8 KVM Switch (DVI video output port), ThinkSystem USB Conversion Cable for Analog KVM, Console switches and cables - Global Console Managers, Global 2x2x16 Console Manager (GCM16) (VGA video output port), Global 4x2x32 Console Manager (GCM32) (VGA video output port), Virtual Media Conversion Option Gen2 (VCO2), Console switches and cables - Local Console Managers, Local 1x8 Console Manager (LCM8) (VGA video output port), Local 2x16 Console Manager (LCM16) (VGA video output port), 0U 36 C13/6 C19 24A/200-240V 1 Phase PDU with NEMA L6-30P line cord, 0U 36 C13/6 C19 32A/200-240V 1 Phase PDU with IEC60309 332P6 line cord, 0U 21 C13/12 C19 32A/200-240V/346-415V 3 Phase PDU with IEC60309 532P6 line cord, 0U 21 C13/12 C19 48A/200-240V 3 Phase PDU with IEC60309 460P9 line cord, 0U 20 C13/4 C19 Switched and Monitored 24A/200-240V/1Ph PDU w/ NEMA L6-30P line cord, 0U 20 C13/4 C19 Switched and Monitored 32A/200-240V/1Ph PDU w/ IEC60309 332P6 line cord, 0U 18 C13/6 C19 Switched / Monitored 32A/200-240V/346-415V/3Ph PDU w/ IEC60309 532P6 cord, 0U 12 C13/12 C19 Switched and Monitored 48A/200-240V/3Ph PDU w/ IEC60309 460P9 line cord, 1U 9 C19/3 C13 Switched and Monitored DPI PDU (without line cord), 1U 9 C19/3 C13 Switched and Monitored 60A 3Ph PDU with IEC 309 3P+Gnd cord, 1U 12 C13 Switched and Monitored DPI PDU (without line cord), 1U 12 C13 Switched and Monitored 60A 3 Phase PDU with IEC 309 3P+Gnd line cord, Ultra Density Enterprise PDUs (9x IEC 320 C13 + 3x IEC 320 C19 outlets), Ultra Density Enterprise C19/C13 PDU Module (without line cord), Ultra Density Enterprise C19/C13 PDU 60A/208V/3ph with IEC 309 3P+Gnd line cord, C13 Enterprise PDUs (12x IEC 320 C13 outlets), DPI C13 Enterprise PDU+ (without line cord), DPI Single Phase C13 Enterprise PDU (without line cord), C19 Enterprise PDUs (6x IEC 320 C19 outlets), DPI Single Phase C19 Enterprise PDU (without line cord), DPI 60A 3 Phase C19 Enterprise PDU with IEC 309 3P+G (208 V) fixed line cord, DPI 30amp/125V Front-end PDU with NEMA L5-30P line cord, DPI 30amp/250V Front-end PDU with NEMA L6-30P line cord, DPI 32amp/250V Front-end PDU with IEC 309 2P+Gnd line cord, DPI 60amp/250V Front-end PDU with IEC 309 2P+Gnd line cord, DPI 63amp/250V Front-end PDU with IEC 309 2P+Gnd line cord, DPI Universal 7 C13 PDU (with 2 m IEC 320-C19 to C20 rack power cord), DPI 100-127V PDU with fixed NEMA L5-15P line cord, Line cords for PDUs that ship without a line cord, RT1.5kVA 2U Rack or Tower UPS (100-125VAC) (8x NEMA, RT1.5kVA 2U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A outlets), RT2.2kVA 2U Rack or Tower UPS (100-125VAC) (8x NEMA 5-20R 16A outlets), RT2.2kVA 2U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A, 1x IEC 320 C19 16A outlets), RT3kVA 2U Rack or Tower UPS (100-125VAC) (6x NEMA, RT3kVA 2U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A, 1x IEC 320 C19 16A outlets), RT5kVA 3U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A, 2x IEC 320 C19 16A outlets), RT6kVA 3U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A, 2x IEC 320 C19 16A outlets), RT8kVA 6U Rack or Tower UPS (200-240VAC) (4x IEC 320-C19 16A outlets), RT11kVA 6U Rack or Tower UPS (200-240VAC) (4x IEC 320-C19 16A outlets), RT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) (4x IEC 320-C19 16A outlets), RT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) (4x IEC 320-C19 16A outlets), ThinkSystem RT3kVA 2U Standard UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets), ThinkSystem RT3kVA 2U Long Backup UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets), ThinkSystem RT6kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output), ThinkSystem RT10kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output), Lenovo ThinkSystem SR550 Server (Xeon SP Gen 1), ThinkSystem 2.5" PM1645a 6.4TB Mainstream SAS 12Gb Hot Swap SSD, 4XB7A17065, ThinkSystem 3.5" PM1645a 6.4TB Mainstream SAS 12Gb Hot Swap SSD, 4XB7A17068, IPMI over LAN is disabled by default, but can be enabled in CTO orders -. * The adapter comes without transceivers or cables; for ordering transceivers or cables, see the adapter product guide, For more information, see the list of Product Guides in the Ethernet Adapters category: 12 DIMM slots (6 DIMM slots per processor). The SR550 server delivers impressive compute power per watt, featuring 80 PLUS Titanium and Platinum redundant power supplies that can deliver 96% (Titanium) or 94% (Platinum) efficiency at 50% load when connected to a 200 - 240 V AC power source. Pointing Device USB - Thai 191 RoHS v2, ThinkSystem Keyboard w/ Int. Our Premier Client services provide large accounts with special handling services to ensure these complex transactions are serviced properly. A Lenovo Technical Account Manager helps you optimize the operation of your data center based on a deep understanding of your business. Provides easy access to upgrades and serviceable parts (such as processors, memory DIMMs, and adapter cards) with tool-less cover removal. * If a 0U PDU is used, the rack cabinet must be at least 1100 mm (43.31 in.) ThinkSystem The following key components are located inside the SR550 server: The following table lists the system specifications for the SR550 server. Processor's integrated memory controllers: Error correction code (ECC), SDDC (for x4-based memory DIMMs), ADDDC (for x4-based memory DIMMs, requires Intel Xeon Gold or Platinum processors), memory mirroring, memory rank sparing, patrol scrubbing, and demand scrubbing. The ThinkSystem SR550 server conforms to the following regulations: Note: For more information on the Energy Star 3.0 certification, refer to the Energy Star 3.0 Certifications for ThinkSystem Servers publication: For customers in China, the ThinkSystem SR590/SR650 Rear HDD Kit Without Fan feature lets add rear drives without additional fans under the following conditions: The 3.5" Rear HDD/SSD Kit is connected to a separate port on the internal storage controller. Depending on the hardware configuration, some server models comply with ASHRAE class A3 and class A4 specifications. https://lenovopress.com/lp1287-lenovo-rack-cabinet-reference, For more information, see the list of Product Guides in the Rack cabinets category: TruDDR4 http://datacentersupport.lenovo.com/us/en/solutions/lnvo-lcp. The following table lists the specifications of the processors for the SR650 server. The UpdateXpress tool is a standalone GUI application for firmware and device driver updates that enables you to maintain your server firmware and device drivers up-to-date and help you avoid unnecessary server outages. It provides functions to collect full system health information (including health status), configure system setting, and update system firmware and drivers. Three (one processor) or four (two processors) non-hot-swap system fans. http://lenovopress.com/LP0904. GPU adapters are supported only with the 1100 W or 1600 W power supplies. Optional Lenovo Business Vantage security software (available only in PRC). An internal storage controller occupies the PCIe slot 7. Flex System Drives (select models) and power supplies. http://lenovopress.com/tips1200. Simplifies servicing, speeds up problem resolution, and helps improve system availability with light path diagnostics. Figure 1. Lenovo will also maintain records of latest patches, critical updates, and firmware levels, to ensure customer's systems are providing business value through optimized performance. Leverage migration assessment planning documents to perform necessary migrations. Pointing Device USB - French 189 RoHS v2, ThinkSystem Keyboard w/ Int. Lenovo experts can seamlessly manage the physical installation of your server, storage, or networking hardware. 4x or 5x P4 GPU adapters: No Additional Air Duct Upgrade Kits are required. Having a trusted partner who can perform regular and detailed health checks is central to maintaining efficiency and ensuring that your systems and business are always running at their best. * Processor details: Processor quantity and model, cores, thermal design power (TDP), and core speed. Health Check supports Lenovo-branded server, storage, and networking devices, as well as select Lenovo-supported products from other vendors that are sold by Lenovo or a Lenovo-Authorized Reseller. ADDDC (for x4-based memory DIMMs; Gold and Platinum processors only). The drive is based on the Lenovo Slim DVD Burner DB65 drive and supports the following formats: DVD-RAM, DVD-RW, DVD+RW, DVD+R, DVD-R, DVD-ROM, CD-RW, CD-R, CD-ROM. The M.2 SSD Thermal Kit is derived by the configurator if M.2 5100 or 5300 SSDs are selected in the initial configurations for server models with 12x LFF drive bays. http://lenovopress.com/tips1200. The following configurations require the single-wide PCIe 3.0 x16 Slot 1: Two double-wide GPUs and one PCIe x16 adapter.